Fiche n 26
8
9
9
10
10
AUTOMATIC TRANSMISSION
Meaning of the bargraphs
Illuminated when the circuit of solenoid valve N 2 is faulty.
- On the keypad enter:
*
- The following will appear on the display:
either:
The circuit of solenoid valve N 2 is short circuited.
or:
The circuit of solenoid valve N 2 is broken.
or:
The circuit of solenoid valve N 2 is operating correctly (the bargraph should not
be illuminated).
Illuminated when the full load (PF) position is recognised by the automatic
transmission computer.
Illuminated when the kickdown compensator supplies its information to the
automatic transmission computer
I I I I M M M M P P P P O O O O R R R R T T T T A A A A N N N N T T T T
: This bargraph is always illuminated for automatic transmissions which
do not have a kickdown compensator.
Illuminated when the no load position (PL) is not validated
(see "erasing the memory and programming the no load and full load positions"
section).
Illuminated when the full load position (PF) is not validated
(see "erasing the memory and programming the no load and full load positions"
section).
2
8
23-198
23