AUTOMATIC TRANSMISSION
23
Fiche n 1
Adjusting the load potentiometer
Connect connector (L) of the adaptor lead (18) to
connector (10) of the load potentiometer.
Do not enter the automatic transmission code.
On the keypad enter:
V
1
Adjustments are performed at full load.
On the upper part of the bargraphs:
- the bargraph located in the left hand column is
moving
- bargraph 5 RH is fixed.
In the full load position, the bargraph of the left
hand column must be aligned with the bargraph
of the right hand column thus illuminating bar-
graphs 5RH and 5LH.
In the full load position, a value between 0 and 3
should be read on the central display (0 being the
optimum setting).
23-143