Verification; Power-Up Test; Operational Test - Avaya PARTNER 1600 DSL MODULE User Manual

Advanced communications system module
Hide thumbs Also See for PARTNER 1600 DSL MODULE:
Table of Contents

Advertisement

Power-up test

Operational
test
Avaya, Inc.
This chapter describes how to verify that the PARTNER ACS
1600 DSL module operates properly after installation. It also
covers maintenance, and how to display the current
configuration. Before you can test the voice capabilities of the
PARTNER ACS 1600 DSL module, you must first provision it
at the voice gateway.
The PARTNER ACS 1600 DSL module shows a brief
indication of normal operation when you first turn on the IAD –
verify that the POWER indicator on the front panel lights
green.
The following procedure assumes that:
You configured Directory numbers (DNs) in the Class 5
switch for the associated POTS ports.
information, see the "WAN configuration" chapter.
You configured PVCs at the DSLAM (defaults = 0, 38 –
data and 0, 39 – voice). For more information, see the
"WAN configuration" chapter.
You configured a data network. For more information,
see the "WAN configuration" chapter.
You have a dedicated communications circuit available
between yourself and a counterpart connected to the
associated voice gateway via the PARTNER ACS 1600
DSL module.
You connected and configured a WAN link at the
associated DSLAM.
"WAN configuration" chapter.
You have a PC that has an Ethernet adapter and runs
a TCP/IP stack. For more information, see the "Getting
started" chapter.
- 165 - PARTNER ACS 1600 DSL module User Guide
11.

Verification

For more information, see the
For more

Advertisement

Table of Contents
loading

This manual is also suitable for:

Partner acs 1600 dsl

Table of Contents