Installing the Hardware
.
Connecting CU1 and CU2 to
the MERLIN LEGEND System
The connection between the CMS PC and the MERLIN LEGEND system uses
the two ports (CU1 and CU2) on the CMS interface card and two DLC opera-
tor jacks on the MERLIN LEGEND control unit. The DLC operator ports used
for CMS must be on the same analog module. Refer to Form 2a, System
Numbering—Station Jacks, for the jacks assigned to CU1 and CU2. Use the
two 14-foot modular cords included with the CMS interface card to make the
connection.
To connect the CMS PC to the MERLIN LEGEND system, complete these
steps:
1. Turn the PC to show the three ports on the CMS interface card.
2. Plug one of the 14-foot modular station cords provided in the CMS
hardware package into the port labeled "CU1" on the CMS interface
card.
3. Plug the other end of the cord into the appropriate DLC operator station
jack on the MERLIN LEGEND control unit.
4. Plug the other 14-foot modular station cord into the port labeled "CU2"
on the CMS interface card.
5. Plug the other end of the cord into the DLC operator station jack on the
MERLIN LEGEND control unit assigned to CU2.
Figure 2-3 shows the connection between the CMS interface card ports CU1
and CU2 and the two DLC operator ports on the MERLIN LEGEND control
unit.
Installation Procedures
2-12