4.15.1 System Redundancy set Command

set

System Redundancy Commands
Sets the parameters for redundant switch mode.
Syntax
set [op_state|mode|heartbeat|revertdelay|redundancy|preempt|virtualip]
set mode <mode>
set op_state <state>
set heartbeat <interval>
set revertdelay <delay>
set redundancy <subnet> <state>
set preempt <mode>
set virtualip <subnet> <ip>
Parameters
mode <mode>
op-state <state>
heartbeat <interval> Sets the heartbeat interval for the switch to <interval> (1–60) seconds.
revertdelay <delay>
redundancy <subnet>
<state>
preempt <mode>
virtualip <subnet>
<ip>
Example
admin(system.redundancy)>set mode standby
can not set the value when the op_state is either upgrade or standalone
admin(system.redundancy)>set op-state redundancy
admin(system.redundancy)>set mode standby
admin(system.redundancy)>
Sets the switch to the <mode>
is either the
primary
or
secondary
This parameter can only be set if the
Sets the redundancy operation state of the switch to one of the following <state>:
• standalone—The switch has no redundancy capabilities and operates
independently of any other WS 2000 switches on the network. This is the default
setting.
• redundancy—Two WS 2000 switches are connected, with one set as a primary
and the other as a standby.
• upgrade—The primary and standby switches must run the same version of the
switch firmware for redundancy to work correctly. If the firmware on only one of
the switches is updated, redundancy is disabled and the Operational State is
automatically set to Upgrade.
Specifies the amount of time <delay>
heartbeat packet before the secondary (standby) switch will take over.
Sets the redundancy state <state>
(s1, s2. s3, s4, s5, s6).
Enables to prevent system stand-by on redundant switches. <mode> can be
enable
or disable.
Sets the virtual IP address to <ip> for each redundant subnet <subnet>.
System CLI Commands Reference
(primary
or secondary). Indicates that the switch
(standby) switch when redundancy is enabled.
op_state
parameter is set to redundancy.
(1–20
minutes) after not receiving a
(enable
or disable) for the subnet <subnet>
4-67