Chapter 2: System Configuration
2.8.1 Configuring the Trap Table
To configure the Trap table, proceed as follows:
1.
Using the arrow keys, highlight the appropriate Trap Destination field.
2.
Enter the IP Address of the workstation that is to receive traps. IP address entries must
follow the DDN format.
For example: 134.141.79.121
3.
Press ENTER. If an invalid entry is entered "INVALID IP ENTERED" is displayed in the
Event Message Line.
4.
Using the arrow keys, highlight the Trap Community Name field. Enter the community
name.
5.
Press ENTER.
6.
Using the arrow keys, highlight the Enable Traps field. Press the SPACE bar to choose
either YES (send alarms from the chassis to the workstation), or NO (prevent alarms from
being sent).
7.
Using the arrow keys, highlight the SAVE field and press ENTER. The message "SAVED
OK" displays on the screen.
The designated workstations now receive traps from the chassis.