Canceling thread breakage at the last stitch

When "115" is input for the end code, the thread breakage does not occur. In this case, every
thread breakage including emergency stop is canceled. Carry out the following setting for
canceling thread breakage at the specified point.
Programming
1.
Create the program 1 stitch (A) before the
desired end point.
2.
Press
3.
Move the work clamp with
stitch length. Press
at point B of the pattern.
Point B is programmed.
4.
Press
.
5.
Move the work clamp with
when the needle point is at given point C.
Inputting the end code
1.
Press
and press
Addition of feed after the last point can cancel thread
breakage at the last stitch.
and press
.
when the needle point is
.
for the
. Press