Chapter 4 Extended Option Output
Setting the extended option output
Items to be set are as follows:
Extended option output number
Operation setting
Output condition
Timer 1
Timer 2
When setting is complete, be sure to press
Extended option output No.
Timer
To cancel the set value, input
To register the setting into the machine, carry out operation of "Writing the extended option
output data" (page 201).
198
Specify a number out of 1 - 16. Refer to "Table of extended
option output" (Refer to page 207.)
Select one out of ON, OFF, FLIP and FLOP with
Input conditions for the extended option output. 3 conditions
can be specified. Refer to "Table of extended option output"
(Refer to page 207.)
Set the time until the output varies after the output
condition is established.
Input the value in unit of 10 ms. Value of 0 or 10 - 2550 ms is
set.
Set the time for implementation of the extended option
output. Input the value in unit of 10 ms. Value of 0 or 10 -
2550 ms is set.
When the value is 0, the output remains varying.
Operation setting
Output setting
Timer 2
and press
Programmer
.
.
.