Vsys Session Limit Overview

Related
Documentation

Example: Configuring Vsys Session Limit (NSM Procedure)

358
Vsys DHCP Enhancement Overview on page 355
Vsys Limitations Overview on page 356
Vsys Session Limit Overview on page 358
The session limits that can be configured for a vsys are displayed in Table 86 on page 358:
Table 86: Vsys Session Limit Configuration Details
Parameters
Description
session max
The session maximum is a number between 100 and the maximum session
number for the overall security system. The default value is the maximum
session number for the overall security system (as if no session limitation is
in force).
reserve
In case of over-subscription, the reserve number is the number of sessions
you reserve or guarantee for the specified vsys. The reserve value is a number
between zero (0) and the maximum number of sessions you allocate for the
specified vsys.
alarm
The alarm threshold is a percentage of the maximum limit that triggers the
alarm. The default value is 100% of the session limit for a configured vsys.
Virtual Routers Overview on page 296
Virtual Router General Properties Overview on page 297
Access List Overview on page 298
Policy-Based Routing Overview on page 351
Vsys DHCP Enhancement Overview on page 355
Vsys Limitations Overview on page 356
To configure the vsys session limit:
In the NSM navigation tree, select Object Manager > VSYS Profile.
1.
Select Vsys Profile Gold (from previous example) and click Edit.
2.
Configure as follows:
3.
For Session Limitation enter 2500 (Maximum) and 2000 (Reserved).
For Alarm, enter 90 (indicates the alarm triggers when 90% of the session maximum
is achieved).
Click OK to apply the settings.