Starting Up the Vehicle
Apply this procedure to start up your vehicle:
1.
Make sure no system will engage and/or start to operate as you start the engine.
2.
Make sure the shut-off valve on the hydraulic tank is fully open before starting the vehicle
(see Figure 2-24).
Figure 2-24
Shut-off valve
N
: The hydraulic tank model may vary according to the options installed.
OTE
Warning!
3.
Start the engine according to the chassis manufacturer's recommendations.
4.
Once the engine is started, wait for the air pressure to build up to at least 70 psi.
In cold weather, let the engine turn at idle a few minutes to warm up the hydraulic oil sufficiently
I
:
MPORTANT
before engaging the pump.
5.
Engage the hydraulic system by pressing the P
The P
UMP
Part # 200277 (rev.00.10.2024)
Failure to fully open the shut-off valve will cause immediate damage to the pump, even if
the pump is turned off.
switch turns from blue to green.
switch (see Figure 2-25).