2. Safety
2.7. Pre-Use Assessment
Descri
The following tests must be conducted before using the robot application for the first time or after
ption
making any modifications.
Verify all safety inputs and outputs are correctly connected.
Test all connected safety input and output, including devices common to multiple
machines or robots, are functioning as intended.
Test emergency stop buttons and inputs to verify the robot stops and the brakes engage.
Test safeguard inputs to verify the robot motion stops. If safeguard reset is configured,
check that it functions as intended.
Look at the initialization screen, activate the reduced input and verify the screen changes.
Change the operational mode to verify the mode icon changes in top right corner of
PolyScope screen.
Test the 3-position enabling device to verify that pressing to the center on position enables
motion in manual mode at a reduced speed.
If the Emergency Stop outputs are used, press the Emergency Stop push-button and
verify that there is a stop of the whole system.
Test the system connected to Robot Moving output, Robot Not Stopping output, Reduced
Mode output, or Not Reduced Mode output to verify the output changes are detected.
Determine the commissioning requirements of your robot application.