Test Output Parameter Groups

This section describes parameters in the test output groups.
The test output parameters are grouped by terminal number.
Item
S Test Output Mode
Fault Action
I/O Comment
Maintenance Counter
Mode Choice
Threshold Maintenance
Counter
4-1 Editing Parameters
Settings
Description
Not used.
The corresponding test output is not
used.
Standard Output
Specifies connecting to the input for a
muting lamp or PLC. Used as a moni-
tor output.
Pulse Test Output
Specifies connecting a device with a
contact output in combination with the
safety input.
Power Supply Output
Specifies connecting to the power sup-
ply terminal of a safety sensor.
The voltages supplied to the IO power
from the test output are output.
Muting Lamp Output
Specifies a muting lamp output.
(Setting supported only
When the output is ON, disconnection
for T3 terminal.)
of the muting lamp can be detected.
Clear off
Sets the output state of the test output
when a communications error occurs.
This parameter is enabled when the
Hold last data
Test Output Channel Mode is set to
Standard Output or Muting Lamp Out-
put.
32 characters max.
Sets an I/O comment for the test out-
put. The I/O comment set here is used
as the I/O tag in the Logic Editor.
Time
Sets the operating mode for the main-
tenance counter.
Count
0 to 4,294,967,295
Sets the threshold value for the main-
hours
tenance counter.
Default
Not used.
Clear off
None
Time
0
75