7-1

Monitoring Functions

Devices supporting DeviceNet Safety hold a variety of status information internally. This information can be
monitored using the Network Configurator.
7-1-1

Monitoring Status

Description
The status of a NE1A-SCPU01 DST1-series Safety I/O Terminal can be monitored using the Network Con-
figurator. If an error occurs in a device, detailed information about the error can be accessed.
Monitoring Status Using the Network Configurator
The user can monitor the status using any of the following methods:
(1) Select a device and select Device - Monitor from the menu bar. Click the Status Tab in the displayed
window.
(2) Select a device and click the Monitor Device Button on the toolbar. Click the Status Tab in the dis-
played window.
(3) Right-click a device and select Monitor from the pop-up menu. Click the Status Tab in the displayed
window.
Device Status
The device status is displayed.
112