Download Print this page

HP ProLiant DL560 Gen11 User Manual page 28

Advertisement

Item
Item
LED
LED
1
Fault/Locate
2
Online/Activity
Drive bay numbering
Drive bay numbering
CAUTION:
CAUTION:
When a server is purchased without any drive installed, some drive bays might be empty while other drive bays might be
populated with drive blanks. To maintain proper system cooling, do not operate the server without a drive or a drive blank
installed.
Subtopics
Subtopics
SFF drive bay numbering
SFF drive bay numbering
E3.S drive bay numbering
E3.S drive bay numbering
SFF drive bay numbering
SFF drive bay numbering
The following drive backplane options are supported in SFF drive configurations:
2 SFF stacked drive backplanes:
24G x4 U.3 NVMe / SAS UBM3 BC
24G x4 U.3 NVMe / SAS UBM6 BC
8 SFF drive backplanes:
8 SFF 24G x1 U.3 NVMe / SAS UBM3 BC
8 SFF 24G x1 U.3 NVMe / SAS UBM6 BC
8 SFF 24G x4 U.3 NVMe / SAS UBM3 BC
8 SFF 24G x4 U.3 NVMe / SAS UBM6 BC
For more information on the drive backplane description, see Drive backplane naming.
16 SFF + 2 SFF drive bay numbering
16 SFF + 2 SFF drive bay numbering
State
State
Definition
Definition
Solid amber
This drive has failed, is unsupported, or is invalid.
Solid blue
The drive is operating normally and being identified by a
management application.
Flashing amber/blue (1
The drive has failed, or a predictive failure alert has been received
flash per second)
for this drive. The drive has also been identified by a management
application.
Flashing amber (1 flash
A predictive failure alert has been received for this drive. Replace
per second)
the drive as soon as possible.
Off
The drive is operating normally and not being identified by a
management application.
Solid green
The drive is online and has no activity.
Flashing green (4
The drive is operating normally and has activity.
flashes per second)
Off
No power present
HPE ProLiant DL560 Gen11 Server User Guide