Download Print this page

HP ProLiant DL560 Gen11 User Manual page 234

Advertisement

Specification
Specification
Input requirements
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Power supply output
Rated steady-state power
Maximum peak power
HPE 1600 W Flex Slot Platinum Hot-plug Low Halogen Power Supply
HPE 1600 W Flex Slot Platinum Hot-plug Low Halogen Power Supply
Specification
Specification
Input requirements
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Maximum rated input power
BTUs per hour
Power supply output
Power supply output
Rated steady-state power
Maximum peak power
Value
Value
100 VAC to 127 VAC
200 VAC to 240 VAC
240 VDC for China only
50 Hz to 60 Hz
11.3 A at 100 VAC
6.1 A at 200 VAC
1103 W at 100 VAC
1064 W at 200 VAC
3764 at 100 VAC
3629 at 200 VAC
1000 W at 100 VAC to 127 VAC
1000 W at 200 VAC to 240 VAC input
1000 W at 100 VAC to 127 VAC
1000 W at 200 VAC to 240 VAC
Value
Value
200 VAC to 240 VAC
240 VDC for China only
50 Hz to 60 Hz
8.7 A at 200 VAC
7.5 A at 230 VAC
1734 W at 200 VAC
1727 W at 230 VAC
5918 at 200 VAC
5891 at 230 VAC
1600 W at 200 VAC to 240 VAC input
1600 W at 240 VDC input
2200 W for 1 ms (turbo mode) at 200 VAC to 240 VAC input
HPE ProLiant DL560 Gen11 Server User Guide
234

Advertisement

loading