4-2
Glue-Related Problems
4-2-9 Spine glue is only partially applied to the book blocks
Where to check
The amount of glue
has dropped to a low
level inside the tank.
Foreign matter has
found its way into the
tank.
4-2-10 The glue does not heat up
Where to check
The circuit breaker
for the heater has
been tripped.
4-2-11 Spine glue thickness is too thin
Where to check
The level of the glue
is too low.
Cause and solution
• If the glue level has dropped inside the tank,
air will be sucked in when the roller turns,
leaving air bubbles on the roller.
• Add more glue.
22064
40209A1
• If milling trim or other foreign matter gets into
the tank, this will block the flow of the glue,
causing the glue on the roller to become
uneven.
• Check inside the tank and under the wipers.
22064
40209A1
Cause and solution
• Check whether the circuit breaker has been
tripped.
(9)
• If it trips again, call your local dealer.
Press
22064
40210A1
Cause and solution
• Add the spine glue before the level of the
glue in the tank drops more than 15mm
Less than
(0.59") below the upper limit.
15 mm
(0.59")
22064
40211A1
Related
item
3-19
—
4
Related
item
5-17
Related
item
3-19
103