Horizon Fitness BOOK BINDER BQ-470 Important Information Manual page 107

Table of Contents

Advertisement

4-1
If an Icon Appears on the Error Screen
Error
Explanation
code
6136
Servo watchdog error
Excessive servo regeneration
6224
warning
6225
Servo overload warning
Servo absolute position counter
6227
warning
6228
Servo parameter warning
6230
Servo mandatory shutdown warning
6231
Servo controller emergency stop
6233
Servo alarm power supply shutoff
Internal ARCNET communication
7100
error (no response)
Control PCB No. 1 ARCNET
7101
communication error
Control PCB No. 2 ARCNET
7102
communication error
Stepper driver No.1
7103
ARCNET communication error
Stepper driver No. 2
7104
ARCNET communication error
i2i PCB ARCNET communication
7105
error
External ARCNET communication
7500
error (no response)
BQ-470 serial communication
7601
send queue error
BQ-470 serial communication
7602
receive queue error
BQ-470 serial communication re-
7603
sending error
9100
Calendar error
9101
Calendar battery error
9105
SI-470A home positioning error
9106
Time out error in initializing
Outside home position value range
9110
error
Outside administrator home
9111
position value range error
9112
SI-470A receive queue error
9113
SI-470A re-sending error
9121
Outside job range error
9131
Touch panel data error
9231
Screen data loading error
Cause and solution
Press the OK button on the screen. Turn the power switch to Off, and wait 10 seconds before
turning it back to On. If the problem occurs again, call the service technician.
The circuit breaker for the clamp rotation motor may have been tripped. Turn the power switch to
Off, and check the circuit breaker. (See Section 5-17.) If the problem occurs again, call the
service technician.
Press the OK button on the screen. Turn the power switch to Off, and wait 10 seconds before
turning it back to On. If the problem occurs again, call the service technician.
Press the OK button on the screen. Check whether the communication cable between the
machine and the i2i PCB is connected properly. Turn the power switch to Off, and wait 10
seconds before turning it back to On. If the problem occurs again, call the service technician.
Press the OK button on the screen. Check whether the communication cable between the
machine and the externally connected device is connected properly. Turn the power switch to
Off, and wait 10 seconds before turning it back to On. If the problem occurs again, call the
service technician.
Press the OK button on the screen. Check the wiring/connection between the BQ-470 and the
SI-470A. Turn the Power switch Off, and wait ten seconds before turning it back again. If the
problem occurs again, call the service technician.
The date/time setting is incorrect. Set the date and time again using the Information – Main
screen. If the error occurs again even after the date and time have been set again, place a
service call.
The battery mounted in the back of the touch panel must be replaced. Call the service technician.
Press the OK button on the screen. Check that there is no obstacle in the way of the slider. If it is
OK, turn the Power switch Off, and wait ten seconds before turning it back again. If the problem
occurs again, call the service technician.
Press the OK button on the screen. Check the wiring/connection between the BQ-470 and the
SI-470A. Turn the Power switch Off, and wait ten seconds before turning it back again. If the
problem occurs again, call the service technician.
There is a problem with memorized home position. Press the OK button on the screen. Turn the
power switch to Off, and wait 10 seconds before turning it back to On. If the problem occurs
again, call the service technician.
There is a problem with memorized home position. Set all the value to 0 on the Information-
Administrator Home Position Correct screen. If the problem occurs again, call the service
technician.
Press the OK button on the screen. Check the wiring/connection between the BQ-470 and the
SI-470A. Turn the Power switch Off, and wait ten seconds before turning it back again. If the
problem occurs again, call the service technician.
There is a problem with memorized job data. Press the OK button on the screen. Turn the power switch to Off, and
wait 10 seconds before turning it back to On. If the problem occurs again, call the service technician.
There is a problem with Touch Panel. Press the OK button on the screen. Turn the power switch to Off, and
wait 10 seconds before turning it back to On. If the problem occurs again, call the service technician.
There is a problem with Touch Panel. Press the OK button on the screen. Turn the power switch
to Off, and wait 10 seconds before turning it back to On. If the problem occurs again, call the
service technician.