Horizon Fitness BOOK BINDER BQ-470 Important Information Manual page 104

Table of Contents

Advertisement

4-1
If an Icon Appears on the Error Screen
Error code
Explanation
Clamp width adjustment
1241
mechanism raising operation error
Clamp width adjustment
1242
mechanism lowering operation
error
Clamp width adjustment opening
1251
operation error
Clamp width adjustment closing
1252
operation error
Servo Motor Encoder Signal Cable
1291
Disconnected
1311
Milling motor inverter alarm
Milling blower motor
1312
inverter alarm
Milling Brake Release
1321
button problem
Roller for side glue and spine glue
1411
inverter alarm
1421
Wiper 1 count not completed error
1431
Wiper 2 count not completed error
Side glue temperature controller
1471
error
1479
Blown side glue thermal fuse
Temperature controller for spine
1481
glue error
1489
Blown thermal fuse for spine glue
1511
Nipping motor inverter alarm
Nipper raising operation error for
1521
book with milling
Nipper lowering operation error for
1522
book with milling
Nipper raising operation error for
1531
book without milling
Nipper lowering operation error for
1532
book without milling
Nipping motor error during nipper
1541
cleaning position operation
Cover feed blower motor inverter
1611
alarm
1621
Cover table raising operation error
Cover table lowering operation
1622
error
94
There is a problem in the clamp width adjustment mechanism. Press the OK button on the screen.
Turn the power switch to Off, and wait 10 seconds before turning it back to On. If the problem
occurs again, call the service technician.
Check that the encoder signal cable for the servo motor is connected correctly.
Press the OK button on the screen. Turn the power switch to Off, and wait 10 seconds before
turning it back to On. If the problem occurs again, call the service technician.
Press the OK button on the screen. Turn the power switch to Off, and wait 10 seconds before
turning it back to On. If the problem occurs again, call the service technician.
The button was pressed while the cover was closed. There is a problem with the Milling Brake
Release button. Press the OK button on the screen. Press the Milling Brake Release button
several times. If the problem persists, turn the power switch to Off, and wait 10 seconds before
turning it back to On. If the problem occurs again, call the service technician.
Press the OK button on the screen. Turn the power switch to Off, and wait 10 seconds before
turning it back to On. If the problem occurs again, call the service technician.
The circuit breaker for the heater for the side glue tank may have been tripped. Turn the power
switch to Off, and check the circuit breaker. (Refer to Section 5-17). If there is nothing wrong with
the circuit breaker, the thermal fuse may have blown. Refer to Section 5-19, and replace the
thermal fuse (supplied accessory).
Press the OK button on the screen. Turn the power switch to Off, and wait 10 seconds before
turning it back to On. If the problem occurs again, call the service technician.
The circuit breaker for the heater for the spine glue tank may have been tripped. Turn the power
switch to Off, and check the circuit breaker. (Refer to Section 5-17). If there is nothing wrong with
the circuit breaker, the thermal fuse may have blown. Refer to Section 5-19, and replace the
thermal fuse (supplied accessory).
Press the OK button on the screen. Turn the power switch to Off, and wait 10 seconds before
turning it back to On. If the problem occurs again, call the service technician.
A problem has occurred during a nipper raising operation. The circuit breaker for the nipper
operation motor may have been tripped. Turn the power switch to Off, and check the circuit
breaker. (Refer to Section 5-17). If the problem occurs again even if nothing is wrong with the
circuit breaker, place a service call.
A problem has occurred during a nipper lowering operation. The circuit breaker for the nipper
operation motor may have been tripped. Turn the power switch to Off, and check the circuit
breaker. (Refer to Section 5-17). If the problem occurs again even if nothing is wrong with the
circuit breaker, place a service call.
A problem has occurred during a nipper raising operation. The circuit breaker for the nipper
operation motor may have been tripped. Turn the power switch to Off, and check the circuit
breaker. (Refer to Section 5-17). If the problem occurs again even if nothing is wrong with the
circuit breaker, place a service call.
A problem has occurred during a nipper lowering operation. The circuit breaker for the nipper
operation motor may have been tripped. Turn the power switch to Off, and check the circuit
breaker. (Refer to Section 5-17). If the problem occurs again even if nothing is wrong with the
circuit breaker, place a service call.
A problem has occurred during movement to the nipper cleaning position. Turn the power switch
to Off, and wait 10 seconds before turning it back to On. If the problem occurs again, call the
service technician.
Press the OK button on the screen. Turn the power switch to Off, and wait 10 seconds before
turning it back to On. If the problem occurs again, call the service technician.
A problem has occurred during the table raising operation. Turn the power switch to Off, and wait
10 seconds before turning it back to On. If the problem occurs again, call the service technician.
A problem has occurred during the table lowering operation. Turn the power switch to Off, and
wait 10 seconds before turning it back to On. If the problem occurs again, call the service
technician.
Cause and solution