Icon
Parameter
Seam Parameter
Stitch length
Needle thread tension
Sewing foot pressure
Sewing foot stroke
Max. Speed
It is possible to reduce the maximum
sewing speed at this point. The maxi-
mum sewing speed can be set in the
software at the Technician level.
98
5.6.5
Setting the Segment parameters
There are various options for setting the parameters in
the segment. The following table lists all possible options.
Settings that are more complex and therefore require further
explanation are described in more detail after the table.
Programming Commander DELTA
Setting
Value range
00.0 - 12.0 [mm]
(depending on the sewing equipment
and the subclass)
Value range
01 - 99
Value range
01 - 20
Value range
1.0 – 9.0 [mm]
Value range
0050 – 3800 [rpm]
(depending on subclass)
Operating Instructions D869 e-con - 00.0 - 06/2023