Dürkopp Adler D869 e-con Operating Instructions Manual page 189

Hide thumbs Also See for D869 e-con:
Table of Contents

Advertisement

Troubleshooting
Code
Type
2183
Error
2184
Error
2185
Error
2187
Error
2188
Error
2201
Error
2205
Error
2221
Error
2222
Error
2230
Error
2231
Error
2252
Error
2271
Error
Operating Instructions D869 e-con - 00.0 - 06/2023
Possible cause
Stepper motor card X30
overcurrent (Stitch length)
Stepper motor card X30
parameter init (Stitch length)
Stepper motor card X30
insulation error
(Stitch length)
Stepper motor card X30
transport interval
failure(Stitch length)
Stepper motor card X30
Reference drive failure
(Stitch length)
Stepper motor X40
reference run timeout
Stepper motor card X40
stepper motor blockage
Stepper motor card X40
encoder plug (Sub-D, 9-pin)
not connected
Stepper motor card X40
flywheel position not found
Stepper motor card X40 not
responding
Stepper motor card X40
parameter init error
Stepper motor card X40
overcurrent
Stepper motor card X40
Watchdog (sewing foot lift)
Remedial action
• Replace control
• Perform a software update
• Check selection of class
• Check motor phase and PE for low-
impedance connection
• Replace encoder
• Replace sewing motor
• Perform a software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Check reference sensor
• Check for stiff movement
• Connect encoder cable to the control, use
the correct interface
• Check stepper motor 1 for stiff movement
• Perform a software update
• Replace control
• Perform a software update
• Check selection of class
• Check for stiff movement
• Perform a software update
• Check selection of class
187

Advertisement

Table of Contents
loading