Dürkopp Adler D869 e-con Operating Instructions Manual page 199

Hide thumbs Also See for D869 e-con:
Table of Contents

Advertisement

Troubleshooting
Code
Type
2687
Error
2688
Error
2901
Error
3010
Error
3011
Error
3012
Error
3020
Error
3021
Error
3022
Error
3030
Error
3104
Warning
3109
Warning
3110
Information Right thread tension magnet
3111
Information Left thread tension magnet
3150
Information Maintenance necessary
Operating Instructions D869 e-con - 00.0 - 06/2023
Possible cause
Stepper motor card X80
transport interval failure
(bottom puller)
Stepper motor card X80
Reference drive failure
(bottom puller)
General Reference Timeout
of the stepper motors
U100 V start-up error
U100 V short circuit
U100 V (I²T) overload
U24 V start-up error
U24 V short circuit
U24 V (I²T) overload
Motor phase failure
Pedal is not in position 0
Operation lock
is not connected
is not connected
Remedial action
• Perform a software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Check the reference sensors
• Disconnect the stepper motor plugs; if
error persists, replace control
• Disconnect motor plug; replace control if
error is not corrected: Replace control
• one or several stepper motors defective
• Disconnect magnet plug; replace control
if error is not corrected: Replace control
• Disconnect magnet plug; replace control
if error is not corrected: Replace control
• One or several magnets defective
• Replace control
• When switching the control on, take your
foot off the pedal
• Check tilt sensor on machine
• Check the connection of right thread
tension magnet
• Check the connection of left thread
tension magnet
• For information on maintenance of the
machine, see the service instructions for
the machine
197

Advertisement

Table of Contents
loading

Table of Contents