Operating Instructions D869 e-con - 00.0 - 06/2023
Setting options Sewing foot stroke
Menu item
Setting 1
linear
Sewing foot stroke
Value range 00 – 09 [mm]
Min. Material
thickness
Value range 00.0 – 10.0 [mm]
Max. Material
thickness
Value range 00.0 – 10.0 [mm]
2.Value
Min. Material
On/Off
thickness
Value range 00.0 – 10.0 [mm]
2. Value
Min. Material
On
thickness
Value range 00.0 – 10.0 [mm]
Setting 2
Maximum sewing foot
stroke reached at the
upper material thickness
limit.
Material thickness at
which the increase in
sewing foot stroke
should start.
Material thickness up
to which the increase in
sewing foot stroke
should occur.
Material thickness from
nd
which the 2
sewing
foot stroke should be
used.
Material thickness from
nd
which the 2
sewing
foot stroke should be
used.