Code
Type
2487
Error
2488
Error
2501
Error
2505
Error
2521
Error
2522
Error
2530
Error
2531
Error
2571
Error
2572
Error
2573
Error
Operating Instructions D869 e-con - 00.0 - 06/2023
Possible cause
Stepper motor card X60
transport interval failure
(Edge guide)
Stepper motor card X60
Reference drive failure
(Edge guide)
Stepper motor card X70
reference run timeout
(upper Puller)
Stepper motor card X70
stepper motor blockage
(upper Puller)
Stepper motor card X70
encoder plug (Sub-D, 9-pin)
not connected
Stepper motor card X70
flywheel position not found
Stepper motor card X70 not
responding
Stepper motor card X70
parameter init error
Stepper motor card X70
Watchdog (upper Puller)
Stepper motor card X70
motor overload / overvoltage /
overcurrent (upper Puller)
Stepper motor card X70
Sewing motor encoder not
connected(upper Puller)
Remedial action
• Perform a software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Check reference sensor
• Check for stiff movement
• Connect encoder cable to the control, use
the correct interface
• Check stepper motor 1 for stiff movement
• Perform a software update
• Replace control
• Perform a software update
• Check selection of class
• Perform a software update
• Check selection of class
• Check selection of class
• Replace control
• Replace encoder
• Replace stepper motor
• Replace control
193