Dürkopp Adler D869 e-con Operating Instructions Manual page 203

Hide thumbs Also See for D869 e-con:
Table of Contents

Advertisement

Troubleshooting
Code
Type
6363
Information No valid data on internal and
6364
Information No valid data on internal
6365
Information Internal EEprom defective
6366
Information Internal EEprom defective
6367
Information Internal EEprom defective
7270
Information External CAN
9310
Error
9320
Error
9330
Information Material thickness sensor
9340
Error
Operating Instructions D869 e-con - 00.0 - 06/2023
Possible cause
external EEprom (software
version is not compatible
with the internal data storage
device, emergency
operating features only)
EEprom and no external
EEprom connected
(the internal data structures
are not compatible with the
external data storage
device)
and external data not valid
(emergency operating
features only)
and external data not valid
(emergency operating
features only)
Tape feeder not connected
Tape feeder in lowered
position
not connected
Remaining thread monitor
not connected
Remedial action
• Check machine ID connection
• Switch off the control, wait until the LEDs
have gone out, and then switch on the
control again
• Software update
• Check machine ID connection
• Switch off the control, wait until the LEDs
have gone out, and then switch on the
control again
• Software update
• Replace control
• Replace control
• Replace control
• Check connection cables
• Perform a software update
• Replace CAN slaves
• Check connection cables
• Perform a software update
• Replace the control of the tape feeder
• No remedial action entered in translation
table
• Check connection cables
• Perform a software update
• Replace material thickness sensor
• Check connection cables
• Perform a software update
• Replace remaining thread monitor