Programming Commander DELTA
Operating Instructions D869 e-con - 00.0 - 06/2023
Setting options Sewing foot stroke
Menu item
Setting 1
linear
Sewing foot stroke
Value range
00 – 09 [mm]
Min. Material
thickness
Value range
00.0 – 10.0 [mm]
Max. Material
thickness
Value range
00.0 – 10.0 [mm]
2.OnOff
Min. Material
thickness
Value range
00.0 – 10.0 [mm]
2.On
Min. Material
thickness
Value range
00.0 – 10.0 [mm]
Setting 2
Maximum sewing foot
stroke reached at the upper
material thickness limit.
Material thickness at which
the increase in sewing foot
stroke should start.
Material thickness up to
which the increase in
sewing foot stroke should
occur.
Material thickness from
nd
which the 2
sewing foot
stroke should be used.
Material thickness from
nd
which the 2
sewing foot
stroke should be used.