118
Setting options Needle thread tension
Menu item
Setting 1
linear
Needle thread tension
Value range 00 – 99
Min.
Sewing speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
Max.
Sewing speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
2.Value
Min.
On/Off
Sewing speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
2. Value
Min.
On
Sewing speed
Value range
0000 – 4000 [rpm]
(depending on subclass)
Programming Commander DELTA
Operating Instructions D869 e-con - 00.0 - 06/2023
Setting 2
Maximum needle thread
tension reached at the
upper speed limit.
Speed at which the
increase in needle thread
tension should start.
Speed up to which the
increase in needle thread
tension should occur.
Speed from which the
nd
2
needle thread tension
should be used.
Speed from which the
nd
2
needle thread tension
should be used.