Code
Type
2675
Error
2676
Error
2677
Error
2678
Error
2679
Error
2680
Error
2681
Error
2683
Error
2684
Error
2685
Error
196
Possible cause
Stepper motor card X80 Init
Position not found
(bottom puller)
Stepper motor card X80 not
Enabled (bottom puller)
Stepper motor card X80 I²t
(bottom puller)
Stepper motor card X80
Encoder failure
(bottom puller)
Stepper motor card X80
Current sensor failure
(bottom puller)
Stepper motor card X80
Incorrect stepper motor
direction of rotation
(bottom puller)
Stepper motor card X80
Reference drive failure
(bottom puller)
Stepper motor card X80
overcurrent (bottom puller)
Stepper motor card X80
parameter init
(bottom puller)
Stepper motor card X80
insulation error
(bottom puller)
Remedial action
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace control
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace encoder
• Replace control
• Replace encoder
• Check if plugs have been mixed up
• Check the wiring in the machine
distributor and change it if necessary
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace control
• Perform a software update
• Check selection of class
• Check motor phase and PE for low-
impedance connection
• Replace encoder
• Replace sewing motor
Operating Instructions D869 e-con - 00.0 - 06/2023