Dürkopp Adler D869 e-con Operating Instructions Manual page 190

Hide thumbs Also See for D869 e-con:
Table of Contents

Advertisement

Code
Type
2272
Error
2273
Error
2274
Error
2275
Error
2276
Error
2277
Error
2278
Error
2279
Error
2280
Error
2281
Error
2283
Error
188
Possible cause
Stepper motor card X40
motor overload / overvoltage /
overcurrent (Sewing foot lift)
Stepper motor card X40
Sewing motor encoder not
connected (Sewing foot lift)
Stepper motor card X40
Sewing motor encoder not
init (Sewing foot lift)
Stepper motor card X40 Init
Position not found
(Sewing foot lift)
Stepper motor card X40 not
Enabled (Sewing foot lift)
Stepper motor card X40 I²t
(Sewing foot lift)
Stepper motor card X40
Encoder failure
(Sewing foot lift)
Stepper motor card X40
Current sensor failure
(Sewing foot lift)
Stepper motor card X40
Incorrect stepper motor
direction of rotation
(Sewing foot lift)
Stepper motor card X40
Reference drive failure
(Sewing foot lift)
Stepper motor card X40
overcurrent (Sewing foot lift)
Remedial action
• Check selection of class
• Replace control
• Replace encoder
• Replace stepper motor
• Replace control
• Perform a software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace control
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace encoder
• Replace control
• Replace encoder
• Check if plugs have been mixed up
• Check the wiring in the machine
distributor and change it if necessary
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace control
Operating Instructions D869 e-con - 00.0 - 06/2023