5-6

Acceleration/deceleration time

5-6-1

Acceleration/Deceleration Time Setting

• Set the motor acceleration/deceleration time.
• The set time here is the acceleration/deceleration time from 0 Hz to the maximum frequency. The
actual acceleration/deceleration time varies depending on the frequency reference value.
• This parameter is for setting the time constant of the primary delay filter with respect to the output
frequency during acceleration/deceleration when V/f control (F42/A14 = 0 to 3) is selected. Set this
parameter when an overshoot or undershoot occurs when the frequency arrives at the target fre-
quency or the rotation of the motor stops and this causes mechanical problems. Setting a large val-
ue stabilizes the output frequency but worsens response.
Parameter
No.
F07
E10
F08
E11
d86
Related functions
*1.
To enable switching to the 1st and 2nd control, allocate "12: SET (2nd control)" to either of input terminal
[DI1] to [DI7].
Additional Information
When a short deceleration time is set, the regenerative amount that is fed back at deceleration
increases. When the regenerative amount exceeds the allowable capacity of the inverter, either
the deceleration time is extended by the setting of Anti-regenerative Control Function Selection
(H69), or overvoltage (OU2) is detected. To shorten the deceleration time, use the regenerative
braking function. For details on the regenerative braking function, refer to 5-12 Regenerative
Braking Function on page 5-75.
M1 Series Standard Type User's Manual (I669)
Output frequency
Maximum Output
Frequency
F03/A01
Starting Frequency
F23/A12
Actual
acceleration
time
F07/E10
RUN command
FW input
Function name
1st Acceleration Time 1
*1
2nd Acceleration Time 1
1st Deceleration Time 1
*1
2nd Deceleration Time 1
Acc/Dec Output Frequency Fil-
ter
Frequency Reference
Actual
deceleration
time
F08/E11
Data
0.00 to 6000 s
0.00 to 6000 s
0.000 to 5.000 s
F03, A01, E01 to E05, E98, E99
5 Basic Settings
Stop Frequency
F25/A63
Time
Default data
Unit
6.00
s
6.00
s
0.000
s
5-39