1 Overview
Item
Maxi-
kW
mum
applica-
HP
ble mo-
tor ca-
*1
pacity
Rated
200 V
output
capacity
240 V
*2
[kVA]
Rated input voltage
Rated input cur-
*4
rent [A]
Rated output voltage
Rated output cur-
*5
rent [A]
Braking torque
*6
[%]
Braking
Regenerative
resistor
braking
circuit
Minimum con-
nection resist-
ance [Ω]
Short circuit current rating
[kA]
Weight [kg]
Dimensions (Width ×
Height) [mm]
Dimensions (Depth) [mm]
*1.
The maximum applicable motor capacity is given for a standard four-phase motor. When selecting an inver-
ter, select not just by kW but also ensure that the inverter rated output current is greater than the motor rat-
ed current.
*2.
In calculating the rated capacity, the rated output voltage is assumed to be 200 V or 240 V.
*3.
A voltage higher than the power supply voltage cannot be output.
*4.
When Carrier Frequency (F26) is set to the following or below, derating is required.
HHD mode...AB001 to A2037: 8 kHz
HND mode...AB001 to A2022: 4 kHz
For derating, refer to A-1 Derating Table on page A-2.
*5.
The following shows the calculated value when the power supply capacity is 500 kVA (10x the inverter ca-
pacity when the inverter capacity exceeds 50 kVA) and when a %X = 5% power supply is connected.
*6.
The numeric value is the average braking torque per individual motor. (Varies according to motor efficiency)
*7.
Allowable ambient temperature of 40°C or below of AB004, AB007, AB015 and AB022.
The rated output current in the HND mode decreases by 2% for every temperature increase of 1°C when
the ambient temperature is 40°C or more.
*8.
The maximum applicable motor capacity is 2.2 kW when the input voltage is 220 to 240 V.
*9.
The maximum applicable motor capacity is 3.0 kW when the input voltage is 220 to 240 V.
1-14
HHD
0.1
0.2
HND
0.2
0.4
HHD
1/8
1/4
HND
1/4
1/2
HHD
0.3
0.6
HND
0.4
0.7
HHD
0.4
0.7
HND
0.5
0.8
*3
HHD
1.8
3.3
HND
3.3
4.9
HHD
1
1.6
HND
1.2
1.9
HHD
150
HND
75
Built-in braking resistor circuit (discharge resistor separately mounted)
100 to 120
0.5
0.5
98
Single-phase 200 V
0.4
0.75
0.55
1.1
1/2
1
3/4
1 1/2
1
1.7
1.2
2.1
1.2
2.1
1.5
2.5
Single-phase 200 to 240 V, 50/60 Hz
5.4
9.7
7.3
13.8
Single-phase 200 to 240 V (with AVR)
3
5
*7
*7
3.5
6.0
100
73
68
100
0.6
0.9
68×127
120
165
M1 Series Standard Type User's Manual (I669)
1.5
2.2
3.7
*8
*9
2
2.7
2
3
5
3
4
2.8
3.8
6.1
3.3
4.2
3.3
4.6
7.3
4
5
16.4
22
45.4
20.2
26
8
11
17.5
*7
*7
9.6
12
70
40
40
48
29
40 to 120
1.4
1.7
3.8
110×130
140×130
180×220
166
156
171
-
-
-
-
-
-
-