6 Vector Control and Applied Functions
Parameter
No.
P55/A55
P56/A56
P65
P74
P85
P87
6-10
Function name
1st Motor Torque Current
under Vector Control/Torque
Current for 2nd Vector Con-
trol
1st Induced Voltage Factor
under Vector Control/
Induced Voltage Factor for
2nd Vector Control
1st PM Motor d-axis Induc-
tance Magnetic Saturation
Correction
1st PM Motor Reference
Current at Starting
1st PM Motor Flux Limitation
Value
1st PM Motor Reference
Current for Magnetic Pole
Detection
Data
0.00 to 2000 A
50 to 100%
0.0 to 100%
(100.0%=No magnetic saturation)
999 (Factory default)
10 to 200%
(Based on the rated current of the mo-
tor)
50.0 to 150.0%
999 (Factory default)
0 to 200%
(Based on the rated current of the mo-
tor)
M1 Series Standard Type User's Manual (I669)
Default data
Unit
Dependent
A
on capacity
Dependent
%
on capacity
999
%
80
%
999
%
0
%