Advertisement

Quick Links

MX
INVERTER
2
B o r n t o d r i v e m a c h i n e s
»
O m r o n Q u a l i t y w i t h a c a p i t a l ' Q '
»
H i g h p ro g ra m m i n g f u n c t i o n a l i ty
»
B u i l t - i n s a f e t y

Advertisement

Table of Contents
loading

Summary of Contents for Omron MX2 - DATASHEET 2

  • Page 1 B o r n t o d r i v e m a c h i n e s » O m r o n Q u a l i t y w i t h a c a p i t a l ‘ Q ’ »...
  • Page 2 • N e a r s t a n d - s t i ll o p s t a r t i n g t e r a t i o n ( 0 o r q u e •...
  • Page 3 • C o n f o r m s t o s a f e S a f e t y i n s t y n o r m I i d e C A T 3 p e r...
  • Page 4 100% Control... High starting torque and torque control capability in open loop mode give you full control of your machine dynamics and performance. Options for all of the major fieldbus systems and a 24 VDC external supply keeps you in full control of your machine operation.
  • Page 5 ...0% risk! Safety is embedded in the MX2, according to ISO 13849-1, Cat 3, with two safety inputs and an External Device Monitoring (EDM) output. No external contactors on the motor side are required, meaning simpler wiring for the user.
  • Page 6 Position and run! The MX2 is a drive and position controller in one, ideal for modular machines where moderate positional accuracy is required. Speed synchronisation is also possible, with no additional programming required. Speed synchronisation Positioning functionality With no external hardware required, and via standard...
  • Page 7 The MX2 gives you the power to create smart solutions using PLC functionality, as standard. Via an intuitive flow chart programming tool, you can create programs with up to 1000 lines of code and with 5 tasks running in parallel. Entry...
  • Page 8: System Configuration

    Born to drive machines • Current vector control • High starting torque: 200% at 0.5 Hz • Double rating VT 120%/1 min and CT 150%/1 min • Speed range up to 1000 Hz • IM & PM motor control • Torque control in open loop vector •...
  • Page 9: Specifications

    50%: feedback <60Hz Forced-air-cooling Self cooling Cooling method Three phase model use forced-air-cooling but single phase model is self cooling. Based on a standard 3-Phase standard motor. Above 400 Hz with some function limitation. 400 V class Three-phase: MX2@ A4004...
  • Page 10 SET (set second motor), 2CH (2-stage accel./decel. command), FRS (free run stop command), EXT (external trip), USP (startup function), CS (commercial power switchover), SFT (soft lock), AT (analog input selection), RS (reset), PTC (thermistor thermal protection), STA (start), STP (stop), F/R (forward/reverse), PID (PID disable), PIDC (PID reset), UP (re- mote control up function), DWN (remote control down function), UDC (remote control data clear), OPE (operator control), SF1~SF7 (multi-stage speed setting;...
  • Page 11 Dimensions φ 2-d φ 4.5 φ 2-d ‚r‚x‚r‚c‚q‚h‚u‚d ‚r‚x‚r‚c‚q‚h‚u‚d ‚q‚t‚m ‚q‚t‚m ‚o‚v‚q ‚o‚v‚q ‚q‚t‚m ‚q‚t‚m ‚o‚v‚q ‚o‚v‚q ‚R‚f‚R‚l‚w‚Q ‚R‚f‚R‚l‚w‚Q ?@ ?@‚h‚m‚u‚d‚q‚s‚d‚q ‚h‚m‚u‚d‚q‚s‚d‚q ‚R‚f‚R‚l‚w‚Q ‚R‚f‚R‚l‚w‚Q ?@ ?@‚h‚m‚u‚d‚q‚s‚d‚q ‚h‚m‚u‚d‚q‚s‚d‚q ‚g‚š ‚g‚š ‚`‚k‚l ‚`‚k‚l ‚g‚š ‚g‚š ‚`‚k‚l ‚`‚k‚l ‚` ‚` ‚o‚q‚f ‚o‚q‚f ‚` ‚` ‚o‚q‚f...
  • Page 12: Option Board

    AX-RAI00740335-DE 180 DC Reactor Dimensions Weight Voltage Reference AX-RC21400016-DE 1.22 AX-RC10700032-DE AX-RC06750061-DE 1.60 AX-RC03510093-DE AX-RC02510138-DE 1.95 AX-RC01600223-DE 108 135 124 120 3.20 200 V AX-RC01110309-DE 5.20 120 152 6.00 AX-RC00840437-DE AX-RC00590614-DE 11.4 150 177 160 115 AX-RC00440859-DE 182. 14.3 1.22...
  • Page 13 Dimensions Weight Voltage Reference AX-RAO16300038-DE 120 1.78 AX-RAO11800053-DE 120 2.35 AX-RAO07300080-DE 120 2.35 400 V AX-RAO04600110-DE 180 AX-RAO03600160-DE 180 AX-RAO02500220-DE 180 AX-RAO02000320-DE 180 11.7 Chokes Reference Motor Dimensions Weight Ø m diameter AX-FER2102-RE < 2.2 AX-FER2515-RE < 15 AX-FER5045-RE < 45 Ø...
  • Page 14: Standard Connections

    Function (signal level) Main circuit power supply input Used to connect line power to the drive. Drives with single-phase 200 V input power use only terminals R/L1 and N (T/L3), terminal R/L1, S/L2, T/L3 S/L2 is not available for these units...
  • Page 15: Control Circuit

    Control Circuit Type Signal name Function Signal level Source type: connecting [P24] to [1]-[7] turns inputs ON Intelligent input common Sink type: connecting [L] to [1]-[7] turns inputs ON Internal 24 VDC 24 VDC, 30mA 24 VDC, 30 mA Multi-function Input selection 1...
  • Page 16 96.6 Forced-air-cooling Cooling Method Self cooling Input AC Reactor AC reactor Power supply MCCB R/L1 S/L2 T/L3 3 phase 200 V class 400 V class Max. applicable Current value Inductance Max. applicable Current value Inductance Reference Reference motor output kW...
  • Page 17: Ordering Information

    DC reactor Motor Output AC reactor Ground Specifications Model Variable torque Constant torque Voltage class Standard Max motor kW Rated current A Max motor kW Rated current A MX2-AB001-E MX2-AB002-E 0.55 MX2-AB004-E Single-phase 200 V 0.75 MX2-AB007-E MX2-AB015-E 11.0 12.0...
  • Page 18 Types Model Description Functions AX-OP05-E LCD remote operator 5 Line LCD remote operator with copy function, cable length max. 3m. 3G3AX-CAJOP300-EE Remote operator cable 3 meters cable for connecting remote operator 3G3AX-OP01 LED remote operator LED remote operator, cable length max. 3m...
  • Page 19 Configuration and monitoring software tool ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice.
  • Page 20 OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu Austria Germany Portugal Turkey Tel: +43 (0) 2236 377 800 Tel: +49 (0) 2173 680 00...