Omron M1 Series User Manual page 225

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

Parameter
No.
Latest Alarm Info. Running Status
X25
1
Latest Alarm Info. Cumulative
X26
Ope. time
Latest Alarm Info. Number of
X27
Startups
Latest Alarm Info. Main Circuit DC
X28
Voltage
Latest Alarm Info. Internal Air
X29
Temperature
Latest Alarm Info. Heat Sink Tem-
X30
perature
M1 Series Standard Type User's Manual (I669)
Function name
Bit15: BUSY (During function
code data writing)
Bit14: -
Bit13: -
Bit12: RL (Communications ef-
fective)
Bit11: ALM (Alarm relay)
Bit10: DEC (During decelera-
tion)
Bit9: ACC (During accelera-
tion)
Bit8: IL (During current limit-
ing)
Bit7: VL (During voltage limit-
ing)
Bit6: TL (Torque limiting)
Bit5: NUV (Main circuit DC
voltage established)
Bit4: BRK (During braking)
Bit3: INT (Inverter shut down)
Bit2: EXT (During DC braking
or during pre-exciting)
Bit1: REV (During reverse op-
eration)
Bit0: FWD (During forward op-
eration)
0 to 655350 hour
0 to 65,535
0.0 to 1,000.0 V
-32768 to 32767
-32,768 to 32,767
Monitor or Data Range
4 Parameter List
Setting
Default
during
Unit
data
RUN
0
-
-
0
-
h
0
-
-
0.0
-
V
0
-
degC
0
-
degC
4-59