4 Parameter List
Parameter
No.
Fifth Last Alarm Info. Output Cur-
X152
rent
Fifth Last Alarm Info. Cumulative
X153
Ope. Time
Fifth last Alarm Info. Main Circuit
X154
DC Voltage
Fifth last Alarm Info. Cumulative
X158
Running time
Fifth Last Alarm Info. Running
X159
Status
4-74
Function name
0.00 to 99.99 A
0 to 655350 hour
0.0 to 1,000.0 V
0 to 655350 hour
Bit15: BUSY (During function
code data writing)
Bit14: -
Bit13: -
Bit12: RL (Communications ef-
fective)
Bit11: ALM (Alarm relay)
Bit10: DEC (During decelera-
tion)
Bit9: ACC (During accelera-
tion)
Bit8: IL (During current limit-
ing)
Bit7: VL (During voltage limit-
ing)
Bit6: TL (Torque limiting)
Bit5: NUV (Main circuit DC
voltage established)
Bit4: BRK (During braking)
Bit3: INT (Inverter shut down)
Bit2: EXT (During DC braking
or during pre-exciting)
Bit1: REV (During reverse op-
eration)
Bit0: FWD (During forward op-
eration)
Monitor or Data Range
M1 Series Standard Type User's Manual (I669)
Setting
Default
during
Unit
data
RUN
0
-
A
0
-
h
0.0
-
V
0
-
h
0
-
-