5 Basic Settings
• Timed operation is performed when "3: Timed operation" is selected at Pattern Operation / Timed
Operation Mode Selection (C21).
Parame-
ter No.
C21
Pattern Operation /
Timed Operation Mode
Selection
C22 to
Pattern Operation
C28
Stage 1 Operation Set-
ting to Pattern Opera-
tion Stage 7 Operation
Setting
C05 to
Multi-step Frequency
C11
Reference 1 to 15
5-34
Function name
0: 1 cycle operation
1: Repetition operation
2: Constant speed operation after 1 cycle opera-
*2
tion
3: Timed operation
0000 to FFFF hex
 
Bit 15: 0 = Forward 1 = Reverse
Bit 14: Fixed to 0 (Not used)
Bit 13 to 12: Acceleration/Deceleration time se-
lection
0=1st Acceleration Time 1 (F07)/1st Decelera-
tion Time 1 (F08)
1 = 2nd Acceleration Time 1 (E10)/2nd Deceler-
ation Time 1 (E11)
2 = 1st Acceleration Time 2 (E12)/1st Decelera-
tion Time 2 (E13)
3= 2nd Acceleration Time 2 (E14)/2nd Decelera-
tion Time 2 (E15)
 
Bit 11 to 10: Minimum unit of operation time
0 = X 0.01
1 = X 0.1
2 = X 1
3 = X 10
Bit 9 to 0: Data part of operation time
When minimum unit 0 (X 0.01);
000 hex to 3E7 hex (0.00 to 9.99)
 
When minimum unit 1 (X 0.1);
064 hex to 3E7 hex (10.0 to 99.9) Note 1
 
When minimum unit 2 (X 1);
064 hex to 3E7 hex (100 to 999) Note 1
When minimum unit 3 (X 10);
064 hex to 258 hex (1000 to 6000) Note 2
Note 1) (0000 hex to 0063 hex)(03E8 hex to
03FF hex) cannot be set.
Note 2) (0000 hex to 0063 hex)(0259 hex to
03FF hex) cannot be set.
0.00 to 590.00 Hz
Data
*1
M1 Series Standard Type User's Manual (I669)
Default
Unit
data
0
-
0
-
0
Hz