Analog input range
0 to 10V
-10 to 10V
0 to 20mA
4 to 20mA
• Analog input signals 0% to 100% are converted at the following full scale, and used by the corre-
sponding functions.
E61, E62, E63
data
0
1
2
3
5
6
7
9
10
11
M1 Series Standard Type User's Manual (I669)
Input signal
Digital value (%)
0
0%
10V
100%
-10
-100%
0
0%
+10V
100%
0
0%
20mA
100%
4
0%
20mA
100%
Description
Frequency command
Auxiliary frequency setting 1
Auxiliary frequency setting 2
PID command
PID feedback
Ratio setting
Analog torque limiter
Torque bias
Torque command
Torque Current Command
Gain/bias setting value
Gain reference value 100% (factory default
value)
Gain 100% (factory default value)
Bias reference value 100% (factory default
value)
Bias 0% (factory default value)
Gain reference value 100% (factory default
value)
Gain 100% (factory default value)
Bias reference value 100% (factory default
value)
Bias 0% (factory default value)
Gain reference value 100% (factory default
value)
Gain 100% (factory default value)
Bias reference value 100% (factory default
value)
Bias 0% (factory default value)
Gain reference value 100% (factory default
value)
Gain 100% (factory default value)
Bias reference value 20%
Bias 0% (factory default value)
Full scale
0 to maximum output frequency [Hz]
Same as above (same as "0: Frequency reference")
Same as above (same as "0: Frequency reference")
Input Terminal [AI1] Analog Input Adjustment Minimum
Scale (C60) to Input Terminal [AI1] Analog Input Ad-
justment Maximum Scale (C59) in the case of the ana-
log input terminal [AI1]
Input Terminal [AI2] Analog Input Adjustment Minimum
Scale (AII) (C66) to Input Terminal [AI2] Analog Input
Adjustment Maximum Scale (AII) (C65) in the case of
the analog input terminal [AI2] (AII)
Input Terminal [AI2] Analog Input Adjustment Minimum
Scale (AIV) (C72) to Input Terminal [AI2] Analog Input
Adjustment Maximum Scale (AIV) (C71) in the case of
the analog input terminal [AI2] (AIV)
Same as above (same as "3: PID command")
0 to 100%
0 to 200%
Same as above (same as "7: Analog torque limiter")
0 to 200%
Same as above (same as "10: Torque command")