Ncu Cleaning - MIMAKI TxF150-75 Operation Manual

Color inkjet printer
Table of Contents

Advertisement

Chapter 4 Maintenance
Open the maintenance cover.
3
Wipe off any ink adhering to the sides of
4
the head and under the carriage.
• Wipe off any ink, dust, ink dry matter and
adhering using a cleaning stick moistened with
maintenance liquid. Wipe off the maintenance
liquid to make sure none remains.
Clean the end side of head and the
guard plate edge (the areas indicated
in red) using a cleaning stick.
Never touch the
nozzle surface!
Clean with a cleaning stick, tweezers, or cloth.
4-6
Wipe off the collected ink and other substances
on the edges of the guard plate. (Arrow in red)
• Never rub the nozzles.
Press the [ENTER] key after cleaning.
5
Close the maintenance cover and press
6
the [ENTER] key.
• After initialization, the machine returns to local
mode.

NCU Cleaning

The NCU uses a sensor to monitor the ink droplets
ejected from the print head nozzles. Continuing to use the
dirty NCU may prevent the nozzle check function from
operating correctly.
• Be careful to avoid leaving fragments from the
cleaning stick behind when cleaning. These
fragments will increase the risk of ejection fail-
ures (e.g., nozzle clogging or deflection).
On the LOCAL mode screen, select
1
[MENU] > [Maintenance], then press the
[ENTER] key.
• The Maintenance menu is displayed.
Select [Station Maint.] > [Carriage Out] >
2
[Station Maint.], then press the [ENTER]
key.
• The carriage moves over the platen.
Clean the NCU.
3
• Wipe off any ink and dust adhering using a
cleaning stick moistened with maintenance liquid.
Wipe off the maintenance liquid. Make sure none
remains.