Ncu Cleaning; Carriage Underside Cleaning - MIMAKI TS100-1600 Operation Manual

Hide thumbs Also See for TS100-1600:
Table of Contents

Advertisement

NCU Cleaning

The NCU uses a sensor to monitor the ink droplets ejected from the print head nozzles. Continuing to use
the dirty NCU may prevent the nozzle check function from operating correctly.
• Be careful to avoid leaving fragments from the cleaning stick behind when cleaning. These
fragments will increase the risk of ejection failures (e.g., nozzle clogging or deflection).
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
• The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Move To Platen Right End], then press the [ENTER] key.
• The carriage moves over the platen.
3
Open the front cover.
4
Clean the NCU.
• Wipe off any ink and dust adhering using a cleaning stick moistened with maintenance liquid. Wipe
off the maintenance liquid. Make sure none remains.
• Insert the cleaning stick as far as the line shown in the illustration.
5
Once cleaning is complete, close the cover, then press the [ENTER] key.

Carriage Underside Cleaning

The underside of the carriage becomes coated with ink wiped off by the wiper. Continuing to use the dirty
carriage underside will rub dried ink and attached dust on to the media, resulting in contaminated prints.
The print head uses an extremely delicate mechanism. Take great care when handling it.
• Be careful to avoid leaving fragments from the cleaning stick behind when cleaning. These
fragments will increase the risk of ejection failures (e.g., nozzle clogging or deflection).
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
• The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Move To Maint. Space], then press the [ENTER] key.
• The carriage moves to the maintenance space.