Advertisement

4
Clean the cap rubber.
• Wipe off any ink and dust adhering using a cleaning stick moistened with maintenance liquid. Wipe
off the maintenance liquid. Make sure none remains.
5
Check to confirm that the cap slider is not tilted once cleaning is complete.
• If the cap slider is tilted, move the slider block to the left or right to correct the tilt.
6
Close the front cover, then press the [ENTER] key.

NCU Cleaning

The NCU uses a sensor to monitor the ink droplets ejected from the print head nozzles. Continuing to use
the dirty NCU may prevent the nozzle check function from operating correctly.
• Be careful to avoid leaving fragments from the cleaning stick behind when cleaning. These
fragments will increase the risk of ejection failures (e.g., nozzle clogging or deflection).
1
On the LOCAL mode screen, select [MENU] > [Maintenance], then press the [ENTER] key.
• The Maintenance menu is displayed.
2
Select [Station] > [Carriage Out] > [Move To Platen Right End], then press the [ENTER] key.
• The carriage moves over the platen.
3
Open the front cover.
Cap rubber