Setting The Co2 Content Manually - Henny Penny SmartCombi GSC62 series Planning And Installation Instructions

Combisteamer (gas)
Hide thumbs Also See for SmartCombi GSC62 series:
Table of Contents

Advertisement

Smart Combi
Classic Combi
1
2
Global Foodservice Solutions
NOTICE
The CO
value must be under 100 ppm during burning, 0–10 ppm is
2
normal.
4. Contact customer service if the CO
6.8 Setting the CO
The CO
content must be set manually if the values differ from those
2
given in the table.
NOTICE
When the CO
must subsequently be remeasured at high power.
Both settings interact with each other.
1. If the CO
2
- Unscrew the cap (1) from the gas valve.
- Adjust the CO
underneath the cap (1). When doing this, only adjust the socket
screw by a maximum of ¼ of a turn.
- Check CO
- Replace the cap (1) on the gas valve.
2. If the CO
2
- Remove the gas orifice.
- Screw in the adjusting screw (2) by approx. 10 mm.
- Set the CO
3. If the CO
2
- Screw in the adjusting screw (2) by approx. 10 mm.
- Set the CO
4. Check CO
Planning and installation instructions
content manually
2
content has been set for low power, the CO
2
content at low power is too high or too low:
content using the hexagonal socket screw
2
content at low power.
2
content at high power is too low:
content.
2
content at high power is too high:
content.
2
content at low and at high power.
2
values are over 100 ppm.
2
2