6-14. FILTER MOTOR RELAY

6-15. GAS CONTROL VALVES

Nov. 2009
This component is located behind the left control panel and
regulates voltage to the filter motor.
Replacement
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit breaker,
or unplug cord at wall receptacle.
1. Remove left side panel.
2. Label and remove wires from relay.
3. Using a 5/16" wrench, remove the nuts securing the relay
and remove relay from fryer.
4. Install new relay in reverse order.
The gas control valve assembly controls the flow of gas to the
pilot and the main burner. The valve has two 24 volt coils,
which are regulated by terminals PV and MV on the valve. For
gas flow to the pilot, 24 VAC must be present between the PV
and COM terminals.For gas flow to the main burner, 24 VAC
must be present between the MV and COM terminals.
TO AVOID INJURY, PROPERTY DAMAGE, OR
EXPLOSION, BEFORE REPLACING STARTING THIS
PROCEDURE, DO THE FOLLOWING:
MOVE THE POWER/PUMP SWITCH TO THE
"OFF"POSITION.
DISCONNECT THE MAIN CIRCUIT BREAKER
AT THE WALL, OR UNPLUG THE POWER CORD.
TURN OFF THE MAIN GAS SUPPLY TO THE FRY-
ER AND DISCONNECT AND CAP THE SUPPLY
LINE TO FRYER.
6-16
Model EEG-142, 143, 144