6-14. FILTER MOTOR RELAY

6-15. GAS CONTROL VALVES

May 2012
This component is located behind the left control panel and
regulates voltage to the filter motor.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove left side panel.
2. Label and remove wires from relay.
3. Using a 5/16" wrench, remove the nuts securing the relay and
remove relay from fryer.
4. Install new relay in reverse order.
The gas control valve assembly controls the flow of gas to the pilot
and the main burner. The valve has two 24 volt coils, which are
regulated by terminals PV and MV on the valve. For gas flow to the
pilot, 24 VAC must be present between the PV and COM terminals.
For gas flow to the main burner, 24 VAC must be present between the
MV and COM terminals.
TO AVOID INJURY, PROPERTY DAMAGE, OR
EXPLOSION, BEFORE REPLACING STARTING THIS PRO-
CEDURE, DO THE FOLLOWING:
• MOVE THE POWER/PUMP SWITCH TO THE "OFF"
POSITION.
• DISCONNECT THE MAIN CIRCUIT BREAKER
AT THE WALL, OR UNPLUG THE POWER CORD.
• TURN OFF THE MAIN GAS SUPPLY TO THE FRYER
AND DISCONNECT AND CAP THE SUPPLY LINE TO
FRYER.
6-16
Model EEG-153, 154
Replacement