A.1 Structure of user data/process data
The SIDOOR controller supports parameter numbers in the range of 0 to 65535. The exact
assignment of the parameter number is described in the section Parameter assignment
(Page 186).
A.1.1.5

Parameter description (PBE)

The notation of the parameter description states the element number of the parameter
description in the IND array subindex.
Table A-11
Element number
0
1
2
3
4
5
6
7
8
9
10 ... 15
The subindex 255 for transferring a complete parameter description or a complete array requires
a variable telegram length which is not currently supported.
The designation ID (element number 1) consists of the following bits:
Bit
0 ... 7
8
9
10
11
12
13
14
15
316
Elements of the parameter description
Description
Reserved
Designation ID
Number of array elements
Reserved
Reserved
Reserved
Reserved
Lower limit value
Upper limit value
Default value (factory setting)
Reserved
Description
Data type of the parameter value
Scaling and major attribute relevant
Write-protected
Additional text available
Reserved
Parameter differs from factory settings
Parameter can only be reset
Parameter is an array
Reserved
Data type
16 bit