The transfer of the parameter values to the retentive storage and the calculation of the related
parameter checksum is only performed in standstill, during initial or normal operation.
4.2.12

Loading of the factory setting

Function description
Loading the factory setting with subsequent restart of the control unit can be triggered with the
service menu "General setup -> Load factory setting" and using the parameter p91.
The value of parameter p100, "Default command mode" is not overwritten in the process since
it is preset in the factory for the control unit variants ATD401W and ATD420W, as well as
ATD430W.
As soon as a parameter of the respective range changes, its checksum is recalculated.
The following functions are performed when factory settings are loaded:
• All parameters (up to p100) are loaded with default values.
• All event and statistical data is deleted.
• All maintenance data (counter and operating hours) is deleted.
• A restart of the control unit is triggered after approx. 18 seconds.
A learn run and a reparameterization have to be performed for the subsequent operation of the
control unit.
Note
After loading the factory setting via the service menu, wait until the control unit has
automatically triggered a restart (duration approx. 18 s). If the supply voltage of the control unit
is switched off prematurely, the loading of the factory setting can be incomplete.
If the reset of the factory setting was incomplete, error code '5' is displayed during the restart of
the control unit with connected motor and the menu language is set to English. If this is not the
case, repeat the loading of the factory setting.
4.3

Extended functions

Introduction
You can use the advanced features described below to implement application-specific
requirements.
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA
SIDOOR functions
4.3 Extended functions
79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents