SIDOOR functions
4.1 Basic functions
The learn run after initial commissioning can be started in the following ways:
• By pressing the learn run button S401 during operation
• Via the service menu "General setup > Start learn run"
• Via technology control word 1 (TSW1) with DCMD signal 4 (Start learn run) (see "DCMD signal
(Page 319)") and DCMD extension bit "special" (see "DCMD extension bits (Page 319)").
The following procedure is recommended for the learn run after initial commissioning:
1. Door is in the closed position
2. Start learn run
Learn run without determination of the weight to be moved (from V1.14)
The function corresponds to the learn run after initial commissioning, except that a previously
stored weight to be moved is not changed.
If the weight to be moved was set manually with the basic parameter editor (see section Basic
parameter editor (Page 106)) or if the door weight to be moved is to remain unchanged for other
reasons, a learn run can be performed without determining the weight to be moved.
The learn run without determining the weight to be moved can be started in the following ways:
• Via the service menu "General setup > Start learn run without mass determination"
• Via technology control word 1 (TSW1) with DCMD signal 9 (Start learn run without mass
determination) (see section "TSW1 - Technology control word 1 (Page 319)")
The following procedure is recommended for learn run without determining the weight to be
moved:
1. Set the weight to be moved via the basic parameter editor.
2. Door is in the closed position
3. Start learn run
Note
This type of learn run is recommended when using the M5 or MDG5 motor, since the weight to
be moved for these motors was usually set manually via the basic parameter editor and should
not be overwritten again by a learn run.
Interrupting the learn run
Users can interrupt the learn run. After an interruption of the learn run, the status display of the
door control unit shows status code "P" (Error in the learn run), status code "_" (Control unit has
no parameters) or status code "U" (Maximum door weight exceeded) (see also section Operating
status display (Page 303)). The learn run can be started again after interruption of the learn run.
The following actions interrupt an active learn run:
• Repeated operation of the learn run button (S401)
• Operating the OPEN or CLOSE service buttons (S402 or S403)