Parameter ID
Adjustment range
p1231
1 ... 100
p1232
1 ... 100
Output transmission
p4602
88...384
ImpulseStop
p1240
1 ... 100
p1241
1 ... 100
Cold-storage function (as of V1.12)
p1250
1 ... 60
p1251
1 ... 60
p1252 (as of
0 ... 65535
V1.14)
Basic parameters
<V1.10: r2101
0 ... 1100
>=V1.10:
p2101
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA
5.9 Operation and configuration of the control unit
Factory set‐
Unit
ting
60
%
60
%
0
mm/rev
50
%
50
%
0
s
0
s
0
ms
1100
Kg
Description
Threshold value for digital detection of external slide
support during the opening movement
(The proportion of force from which AssistedDrive is
detected in relation to the learnt reference value)
Threshold value for digital detection of external slide
support during the closing movement
(The proportion of force from which AssistedDrive is
detected in relation to the learnt reference value)
M3, MDG3, M4, MDG4, M5 and MDG5 motors
The permissible values are between
88...384 mm/rev.
After change of the output transmission ratio, a learn
run must be carried out or the basic parameters must
be adjusted and confirmed.
Limit value for digital detection of an external oppos‐
ing force during the opening movement
(The proportion of force before ImpulseStop is detec‐
ted in relation to the learnt reference value/friction
force)
Limit value for digital detection of an external oppos‐
ing force during the closing movement
(The proportion of force before ImpulseStop is detec‐
ted in relation to the learnt reference value/friction
force)
"Standard" hold-open time in the cold storage function
in seconds.
As soon as the door receives the open status, the speci‐
fied time starts running and closes automatically when
the time has elapsed. If 0 s is specified, the function is
deactivated.
"Cord-operated switch" hold-open time in the cold
storage function in seconds.
As soon as the door receives the open status, the speci‐
fied time starts running and closes automatically when
the time has elapsed. If 0 s is specified, the function is
deactivated.
Period for issuing the command "Close" (p20059) in
the closed position.
0 = No closing command
65535 = Continuous closing command
Effective door weight
As of V1.10: Writable
Controllers
193