ATD420W / ATD430W Access protection to the parameters
The write protection must be activated via parameter p90 for the SIDOOR ATD420W and
ATD430W controllers. This way the change of parameters is blocked via the service menu.
Note
After the optimal parameter settings have been determined, note them in the configuration
protocol (see appendix Configuration record (Page 339)). Have this record to hand when you call
the Hotline.
Note
Parameter changes
Parameters should always be adjusted during normal operation with the door at standstill,
because the controller then accepts the values immediately.
As of V1.09: The parameter changes are also applied in initial mode with standstill of the door.
5.9.1

Service buttons

Overview
H401
Figure 5-8
5.9.1.1

Operation using service buttons

7-segment display "H401"
You can see the operating states on the "H401" 7-segment display. You can find the description
of the 7-segment display in the section Operating state display (Page 303).
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA
S401
S402
S403
LEARN RUN OPEN
CLOSE
7-segment display
Learn run button
Service button OPEN
Service button CLOSE
Overview of minimal editor
5.9 Operation and configuration of the control unit
Controllers
177