5.5 Relay and fieldbus interfaces
LED signals
The following five status LEDs are available on the PROFINET module:
LED
Color
Description
H1
Green
Relay K1 picked up
LED H1 switches on when the controller has detected the
CLOSED position and the pulse generator ceases to output
pulses. The LED H1 is controlled by the basic module (signal
X200.11).
H2
Green
Relay K2 picked up
LED H2 switches on when the current distance of the door
to the OPEN position falls below 2 cm and the relay has
switched on. The LED H2 is controlled by the basic module
(signal X200.9).
H3
Green
Valid incoming telegram
LED H3 is controlled by the basic module (signal X200.12),
and indicates the communication status. The LED flashes to
indicate incoming, valid telegrams. Each signal change
stands for such a telegram.
H1011 Green
Port 1: LINK
H1012 Orange
Port 1: ACT
H1021 Green
Port 2: LINK
H1022 Orange
Port 2: ACT
H1300 Green
Power on
H1301 Red
"Bus error" PROFINET communication disrupted
The H1301 LED flashes red in the event of a PROFINET com‐
munication error.
H1302 Red
"Group error" internal communication disrupted
The H1302 LED flashes red in the event of an internal com‐
munication error.
Network structure/network topologies
The ATD430W IO device supports the star, line, tree and ring structure network topologies.
The IO device has an integrated switch for the line and ring structures. The MRP redundancy
process is used in the case of the ring structure. In this case, the IO device is the MRP client and
cannot be used as the redundancy manager (MRP manager). This must be provided for
separately in the network structure.
GSD file
The characteristic communication features of the ATD430W IO device are specified in the form
of an electronic device data sheet (device master data file, GSD file). The GSD file has been
certified by the ComDeC test center for PROFINET field devices according to EN 61158 and
IEC 61784.