Power supply

7.5 Building DC voltage supply

Order number
Product
Power supply, type
Installation
Electrical accessories
Mechanical accessories
Other information
7.5
Building DC voltage supply
Connector pin assignment
SELV
7.5.1

Power supply requirements

NOTICE
The DC power supply for the SIDOOR ATD4xxW controller may be used only with firmware
version ATD4xxW > = 1.04.
The following requirements must be met by the building DC power supply:
Supply voltage
In normal operation a non-grounded SELV voltage according to EN 61010-2-201:2018, NFPA
environment UL61010-2-201: 1st Edition 2014 with a typical voltage of 36 V is to be used.
Note 1: Operation of the SIDOOR device is possible down to 19.2V. However, this is associated
with performance loss for the drive with respect to the achievable forces, speeds and
acceleration.
264
6EP3446-8SB10-0AY0
SITOP PSU8200
36 V/13 A
Snaps onto DIN rail EN 60715 35x7.5/15
Buffer module
Device identification label 20 mm × 7 mm, pale
turquoise 3RT1900-1SB20
Specifications at rated input voltage and ambient
temperature +25 °C (unless otherwise specified)
Slot
X3
1
+
2
FE
3
-
Function
Plus
Functional grounding
Minus
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA