Automatic Impulsedrive; Impulsestop - Siemens SIDOOR ATD4 W Series System Manual

Automatic door control units
Table of Contents

Advertisement

Both analyses use a sign to distinguish the directions.
4.3.2

Automatic ImpulseDrive

Function description
The automatic ImpulseDrive system generates a drive order based on the ImpulseDrive
detection.
If an external pulse is detected by the ImpulseDrive analysis procedure, the automatic
ImpulseDrive system generates a drive order with a normal driving profile. Both ImpulseDrive
detection output signals, IMPDRVVelo and IMPDRVIncr, are evaluated. If an enable command is
present, the automatic system initiates opening or closing with a normal drive profile.
The automatic ImpulseDrive can only be used with active enable. The enabling signal (DCMD :=
7) is an element of the DCMD signal (see Table A-16 DCMD signal (Page 319)).
Note
The configuration of the ImpulseDrive detection has a direct effect on the automatic
ImpulseDrive system.
Figure 4-5
4.3.3

ImpulseStop

Function description
The ImpulseStop analysis process detects and analyzes external forces acting on the door system/
drive system.
In conjunction with the automatic ImpulseStop system (see section Automatic ImpulseStop
(Page 82)), it is possible to stop a door by gently jerking it (against the direction of travel).
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA
Automatic ImpulseDrive system
SIDOOR functions
4.3 Extended functions
81

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents